The ExZone Ltd
Ph. +44 (0)845 271 4141    Email: sales@theexzone.com
             

EXEL Series Emergency ZONE 1 and ZONE 2 EEx ed IIC ATEX II 2GD Flourescent Fitting

EXEL.thumb1193268635471fd59bc6051.jpg
View larger imageView larger image
    

 Classification   Group II Category 2GD 
 Installation   Zone 1 - Zone 2 (Gas) Zone 21 - Zone 22 (Dust) 
 Marking   CE Ex II 3GD Ex nA II T4/T5 - Ex tD A22 IP 66 
     CE 0722 Ex II 2GD - Ex de mb IIC T4 Gb - Ex tb IIIC T70°C Db IP66 (*) 
     CE 0722 Ex II 2GD Ex de IIC T4 Gb - Ex tb IIIC IP66 (**) 
     (*) Marking valid for lighting fixtures with operating type normal and normal + emergency. (**) Marking valid only for lighting fixtures with operating type emergency and emergency with batteries housed in separate box. 
 Certification   ATEX CESI 03 ATEX 074 
     IECEx CES 07.0001 
     GOST R AVAILABLE 
     BRAZILIAN DNV 12.0055 X 
 Standards   CENELEC EN60079-0: 2012, EN60079-1: 2007, EN60079-7: 2007, EN60079-18: 2009, EN6007931: 2009, EN61000-3-2, EN60598-1:2008+A11:2009, EN60598-2-22:1998+ A1:2008, EN60598-2-1:1989, EN61547:2009 and DIRETTIVA EUROPEA 94/9/EC: 1994. IEC60079-0:2011, IEC60079-1 
     European Directive 2006/95 Low voltage 
     European Directive 2004/108 Electromagnetic compatibility 
     European Directive 2003/108 WEEE Waste electrical and electronic equipment 
     European Directive 2011/64 RoHS 
 Ambient Temp.   Normal operation -40°C +50°C (T5) Emergency operation -20°C +50°C (T5)  
 Class Temperature   135°C (T4) 100°C (T5) 
 Degree of protection   IP66 


 CODE: EXELE

 Product options
 
Type: 
Lamp Wattage/Qty: 
Battery Pack: 


Qty   
 Add to Enquiry Form 
 

EXEL series increased safety bi-pin fluorescent lighting fixture have a Cortem electronic ballast system that complies with Atex Directive 94/9/EC:1994. They can be installed in hazardous zones 1, 2, 21 and 22 where a high degree of protection and resistance against corrosion is required such as in chemical and petrochemical plants, offshore and on-shore plants, processing areas in food industries etc… Fluorescent tubes that reach the end of their working lives are safely monitored and switched off by means of the EOL (End-Of-Life) system. The fact that they have different voltage ratings means they can be used wordwide. Thanks to the double channel ballast design, if one of the tubes stops working, the other continues working independently. As cable entries/exits are fitted to both sides of the fixture body, installation is simple and fast. The transparent cover is clipped into place on both sides of the fixture body with 8 clips on the 18W and 14 on the 36W unit. This ensures excellent protection against dust andwater over time despite any degradation caused by ageing. For this very reason, these units are often installed in water purification plants and in areas that are hazardous for ships and ferries. A safety switch is housed inside the fixture that automatically cuts off the power supply when the fixture is opened to replace a fluorescent tube and/or an electrical component. EXEL...E series is fitted with a Ni-Cd battery and electronic inverter for use in emergency operation. The operating time under emergency operation can be selected depending on requirements and can last from a minimum of 90 minutes to a maximum of 200 minutes. A red LED warning light comes off if the battery needs
to be replaced due to a short circuit or if the battery itself is dead.

APPLICATION SECTORS
Offshore plants
Farm produce applications
Onshore plants
Low temperatures
Chemical and petrochemical plants
Waste water purification
Naval installations

MECHANICL FEATURES
Body: Black shock and UV resistant fibreglass reinforced anti-static polyester resin
Diffuser: Transparent polycarbonate, shock and UV resistant
Protected opening system: Sliding system operated by a hexagonal-head tool (for safety reasons, the fixture cannot be opened
without
Gasket: Acid/hydrocarbon resistant expanded silicone
Internal reflector: White painted aluminium
Inner frame: Extruded aluminium
Bolts and screws: Stainless steel
Entries: 4 x Ø25.5 entries (suitable for ISO M25 x 1.5 threads). Lighting fixture kit contains 3 model PLG2IXEP
plugs and 2 model UNI21XE cable glands for non-armoured cable
Mounting: Nickel plated brass inserts with 2 x M8 holes

ACCESSORIES AVAILABLE / SPECIAL REQUESTS
2 pin Ø26 fluorescent tubes model T8
Installation brackets
Grey polyester resin body (code EXEL-118EE4G)
Rated voltage: 277 V with electronic double channel ballast (code EXEL-236EF4/277)
Cable entry: 4 x Ø20.5 holes. Lighting fixture kit contains 3 model PLG1IXEP plugs and 2 model UNI1.1XE cable
glands for non-armoured cable (code EXEL-118EE4/20)


Certification II 2GD EEx ed IIC T5 IP66
Standards

EN 50019: 2000

EN 50014: 1997 + A1...A2

EN 50018: 2000

ATEX 94/9/EC: 1994

Area Classification Zone1 and Zone 2
Ingress Protection IP66
Max Surface Temp 100oC(T5)
Ambient Temp -40oC to +50oC
Lampholder Two-pin G13
Lamp Types Flourescent Tubes
Lamp Wattages 18W or 36W
Voltage 230 VAC, 110/230VAC
Frequency 50/60 Hz
Material Polyester Resin with Fibreglass
Coating -

Single and double tube
Code Dimensions mm Type of ballast N° of lamps Power suply Watt Weight Kg mm
A A1 B C
EXEL-118 785 420 185 155 electronic 1 110/240V 50/60Hz 18 5 195x155x820
EXEL-136 1370 720 185 155 electronic 1 110/240V 50/60Hz 36 8 196x155x1400
EXEL-218 785 420 185 155 electronic single channel 2 110/240V 50/60Hz 18 5.5 196x155x820
EXEL-236 1370 720 185 155 electronic single channel 2 110/240V 50/60Hz 36 8.5 196x155x1400
Single and double tube with emergency unit
Code Dimensions mm  Operating type N° of lamps Power suply Watt Discharge time minutes Weight Kg mm
A A1 B C
EXEL-118EF4 785 420 185 155 normal+emergency 1 110/240V 50/60Hz 18 120’ 6.91 196x155x820
EXEL-136EF4 1370 720 185 155 normal+emergency 1 110/240V 50/60Hz 36 90’ 10.1 196x155x1400
EXEL-218EF4 785 420 185 155 normal+emergency 2 110/240V 50/60Hz 18 120’ 7 196x155x820
EXEL-236EF4 1370 720 185 155 normal+emergency 2 110/240V 50/60Hz 36 90’ 9.61 196x155x1400
EXEL-118EE4 785 420 185 155 emergency only 1 110/240V 50/60Hz 18 120’ 6.8 196x155x820
EXEL-136EE4 1370 720 185 155 emergency only 1 110/240V 50/60Hz 36 90’ 8.3 196x155x1400
EXEL-118EF7 785 420 185 155 normal+emergency 1 110/240V 50/60Hz 18 200’ 7.5 196x155x820
EXEL-136EF7 1370 720 185 155 normal+emergency 1 110/240V 50/60Hz 36 180’ 10.51 196x155x1400
EXEL-218EF7 785 420 185 155 normal+emergency 2 110/240V 50/60Hz 18 200’ 7.42 196x155x820
EXEL-236EF7 1370 720 185 155 normal+emergency 2 110/240V 50/60Hz 36 180’ 10.2 196x155x1400
EXEL-118EE7 785 420 185 155 emergency only 1 110/240V 50/60Hz 18 200’ 6 196x155x820
EXEL-136EE7 1370 720 185 155 emergency only 1 110/240V 50/60Hz 36 180’ 11.5 196x155x1400
Single and double lamp units with separate emergency battery pack for temperatures of -20°C to + 55°C
EXEL-118EF4E 785 420 185 155 normal+emergency 1 110/240V 50/60Hz 18 120’ 7 200x170x950
EXEL-136EF4E    1370 720 185 155 normal+emergency 1 110/240V 50/60Hz 36 90’ 10 200x170x1550
EXEL-218EF4E 785 420 185 155 normal+emergency 2 110/240V 50/60Hz 18 120’ 7.5 200x170x950
EXEL-236EF4E    1370 720 185 155 normal+emergency 2 110/240V 50/60Hz 36 90’ 10.5 200x170x1550
EXEL-118EE4E 785 420 185 155 emergency only 1 110/240V 50/60Hz 18 120’ 7 200x170x950
EXEL-136EE4E    1370 720 185 155 emergency only 1 110/240V 50/60Hz 36 90’ 10 200x170x1550
EXEL-118EF7E 785 420 185 155 normal+emergency 1 110/240V 50/60Hz 18 200’ 7.5 200x170x950
EXEL-136EF7E    1370 720 185 155 normal+emergency 1 110/240V 50/60Hz 36 180’ 10.5 200x170x1550
EXEL-218EF7E 785 420 185 155 normal+emergency 2 110/240V 50/60Hz 18 200’ 11 200x170x950
EXEL-236EF7E    1370 720 185 155 normal+emergency 2 110/240V 50/60Hz 36 180’ 11.5 200x170x1550
EXEL-118EE7E 785 420 185 155 emergency only 1 110/240V 50/60Hz 18 200’ 7.5 200x170x950
EXEL-136EE7E    1370 720 185 155 emergency only 1 110/240V 50/60Hz 36 180’ 11.5 200x170x1550

ILLUSTRATION DESCRIPTION MODEL FEATURES CODE
 undefined Tri-phosphor fluorescent tubes G13 fitting 18 W 1350 lm LAMPL18W21
36 W 3350 lm LAMPL36W21
58W 5200 lm LAMPL58W21
undefined
Tige Length:250 mm Material:galvanised steel BRF8MIN/250
undefined
Type U bracket   Material:galvanised steel G-244
undefined
Eyebolt   Material:galvanised steel GOF-M6
undefined
Type V bracket   Material:galvanised steel G-263
 undefined Type D bracket   Material:galvanised steel G-258
 undefined Type P bracket   Material:galvanised steel G-0480
undefined
Non armoured cable gland complete with rubbers, seal and lock nut PG 13.5 Ex e II IP 66/68 (std. range cable 6-12) UNP4XE
 undefined Plug with seal and lock nut PG 13.5 Ex e II IP 66/68 PLG4PXEP
undefined
 Transparent
diffuser
18 W Material: polycarbonate B18-363
36 W B36-363
undefined  Reflector 18 W Material: white plastic
coated aluminium
B18-0213
36 W B36-0213
undefined Safety switch:
Ex de
18 W
36 W
2 for normal lamps
4 for emergency
lamps
M-0530/A
solo per
36 W EF
2xM-0530/A
+ 2xM-0530
M-0530
 undefined Inverter fixing
bracket
  Material: nylon B-380

undefined
Hexagonal-head tool Hexagon 10

CLAFT10
undefined Lamp holder G13 250 V - 4 A G-0312E/..
undefined
Electronic inverter
110/240 V
50/60 Hz
EI-58
undefined Battery pack   4 Ah 6V NiCd G-0309B
7 Ah 6V NiCd G-0309
undefined Double channel
electronic ballast
1 x 18 W 110/240 V
50/60 Hz
EB4118/M
2 x 18 W EB4218/M
1 x 36 W EB4136/M
2 x 36 W EB4236/M
undefined Double channel
resin-bonded
electronic ballast
1 x 18 W
2 x 18 W
1 x 36 W
2 x 36 W
110/240 V 50/60 Hz EBV-1
277 V 50/60 Hz EBV-277 (Work in
progress)



 
Site map